| .. _raid:
 | ||
| 
 | ||
| ######
 | ||
| RAID-1 
 | ||
| ######
 | ||
| 
 | ||
| A Redundant Array of Independent Disks (RAID) uses two or more hard disk drives 
 | ||
| to improve disk speed, store more data, and/or provide fault tolerance. 
 | ||
| There are several storage schemes possible in a RAID array, each offering a 
 | ||
| different combination of storage, reliability, and/or performance. 
 | ||
| The VyOS system supports a “RAID 1” deployment. RAID 1 allows two or more 
 | ||
| disks to mirror one another to provide system fault tolerance. In a RAID 1 
 | ||
| solution, every sector of one disk is duplicated onto every sector of all 
 | ||
| disks in the array. Provided even one disk in the RAID 1 set is operational, 
 | ||
| the system continues to run, even through disk replacement (provided that the 
 | ||
| hardware supports in-service replacement of drives). 
 | ||
| RAID 1 can be implemented using special hardware or it can be implemented in 
 | ||
| software. The VyOS system supports software RAID 1 on two disks.
 | ||
| The VyOS implementation of RAID 1 allows the following:
 | ||
| 
 | ||
| * Detection and reporting of disk failure
 | ||
| * The ability to maintain system operation with one failed disk
 | ||
| * The ability to boot the system with one failed disk
 | ||
| * The ability to replace a failed disk and initiate re-mirroring
 | ||
| * The ability to monitor the status of remirroring
 | ||
| 
 | ||
| .. _raid_instalation:
 | ||
| 
 | ||
| Installation Implications
 | ||
| =========================
 | ||
| 
 | ||
| The VyOS systems installation utility provides several options for installing 
 | ||
| to a RAID 1 set. You can: 
 | ||
| 
 | ||
| * Use the install system to create the RAID 1 set 
 | ||
| * Use the underlying Linux commands to create a RAID 1 set before running the 
 | ||
|   install system command.
 | ||
| * Use a previously-created RAID 1 set.
 | ||
| 
 | ||
| .. note:: Before a permanent installation, VyOS runs a live installation
 | ||
| 
 | ||
| Configuration
 | ||
| =============
 | ||
| 
 | ||
| Single disk, install as normal 
 | ||
| ------------------------------
 | ||
| 
 | ||
| When the VyOS system is installed, it automatically detects the presence of two 
 | ||
| disks not currently part of a RAID array. In these cases, the VyOS 
 | ||
| installation utility automatically offers you the option of configuring RAID 1 
 | ||
| mirroring for the drives, with the following prompt.
 | ||
| 
 | ||
| .. code-block:: none
 | ||
| 
 | ||
|    Would you like to configure RAID 1 mirroring on them?
 | ||
| 
 | ||
| * If you do not want to configure RAID 1 mirroring, enter “No” at the prompt
 | ||
|   and continue with installation in the normal way.
 | ||
| 
 | ||
| Empty 2+ Disk 
 | ||
| -------------
 | ||
| 
 | ||
| If VyOS system detect two identical disks that are not currently part of a 
 | ||
| RAID-1 set, the VyOS installation utility automatically offers you the option
 | ||
| of configuring RAID 1 mirroring for the drives, with the following prompt. 
 | ||
| 
 | ||
| .. code-block:: none
 | ||
| 
 | ||
|    Would you like to configure RAID 1 mirroring on them? 
 | ||
| 
 | ||
| 1 - To create a new RAID 1 array, enter “Yes” at the prompt. If the system 
 | ||
| detects a filesystem on the partitions being used for RAID 1 it will prompt you 
 | ||
| to indicate whether you want to continue creating the RAID 1 array. 
 | ||
| 
 | ||
| .. code-block:: none
 | ||
| 
 | ||
|    Continue creating array?
 | ||
| 
 | ||
| 2 - To overwrite the old filesystem, enter “Yes”. 
 | ||
| 
 | ||
| 3 - The system informs you that all data on both drives will be erased. You are 
 | ||
| prompted to confirm that you want to continue
 | ||
| 
 | ||
| .. code-block:: none
 | ||
| 
 | ||
|    Are you sure you want to do this?
 | ||
| 
 | ||
| 4 - Enter “Yes” at the prompt to retain the current VyOS configuration once 
 | ||
| installation is complete. Enter “No” to delete the current VyOS
 | ||
| configuration. 
 | ||
| 
 | ||
| .. code-block:: none
 | ||
| 
 | ||
|    Would you like me to save the data on it before I delete it?
 | ||
| 
 | ||
| 5 - Enter “Yes” at the prompt to retain the current VyOS configuration once 
 | ||
| installation is complete. Enter “No” to delete the current VyOS configuration.
 | ||
| 
 | ||
| 6 - Continue with installation in the normal way.
 | ||
| 
 | ||
| 
 | ||
| Present RAID-1
 | ||
| --------------
 | ||
| 
 | ||
| When the VyOS software on a system with a RAID 1 set already configured, 
 | ||
| the installation utility will detect the array and will display the following 
 | ||
| prompt: 
 | ||
| 
 | ||
| .. code-block:: none
 | ||
| 
 | ||
|    Would you like to use this one? 
 | ||
| 
 | ||
| 1 - To break apart the current RAID 1 set, enter “No” at the prompt. The 
 | ||
| 
 | ||
| installation utility detects that there are two identical disks and offers you 
 | ||
| the option of configuring RAID 1 mirroring on them, displaying the following 
 | ||
| prompt: 
 | ||
| 
 | ||
| .. code-block:: none
 | ||
| 
 | ||
|    Would you like to configure RAID 1 mirroring on them? 
 | ||
| 
 | ||
| 2 - To decline to set up a new RAID 1 configuration on the disks, enter “No” 
 | ||
| at the prompt. The system prompts you to indicate which partition you would 
 | ||
| like the system installed on. 
 | ||
| 
 | ||
| .. code-block:: none
 | ||
|    
 | ||
|     Which partition should I install the root on? [sda1]: 
 | ||
| 
 | ||
| 3 - Enter the partition where you would like the system installed. The system 
 | ||
| then prompts you to indicate whether you want to save the old configuration
 | ||
| data. This represents the current VyOS configuration. 
 | ||
| 
 | ||
| .. code-block:: none
 | ||
| 
 | ||
|    Would you like me to save the data on it before I delete it? 
 | ||
| 
 | ||
| 4 - Enter “Yes” at the prompt to retain the current VyOS configuration once 
 | ||
| installation is complete. Enter “No” to delete the current VyOS configuration. 
 | ||
| 
 | ||
| 5 - Continue with installation in the normal way.
 | ||
| 
 | ||
| 
 | ||
| Detecting and Replacing a Failed RAID 1 Disk
 | ||
| --------------------------------------------
 | ||
| 
 | ||
| The VyOS system automatically detects a disk failure within a RAID 1 set and 
 | ||
| reports it to the system console. You can verify the failure by issuing the
 | ||
| show raid command.
 | ||
| 
 | ||
| To replace a bad disk within a RAID 1 set, perform the following steps:
 | ||
| 
 | ||
| 1 - Remove the failed disk from the RAID 1 set by issuing the following 
 | ||
| command:
 | ||
| 
 | ||
| .. opcmd:: delete raid <RAID‐1‐device> member <disk‐partition>
 | ||
| 
 | ||
|    where RAID-1-device is the name of the RAID 1 device (for example, md0) and 
 | ||
|    disk-partition is the name of the failed disk partition (for example, sdb2).
 | ||
| 
 | ||
| 2- Physically remove the failed disk from the system. If the drives are not 
 | ||
| hot-swappable, then you must shut down the system before removing the disk.
 | ||
| 
 | ||
| 3 - Replace the failed drive with a drive of the same size or larger.
 | ||
| 
 | ||
| 4 - Format the new disk for RAID 1 by issuing the following command:
 | ||
| 
 | ||
| .. opcmd:: format disk <disk‐device1> like <disk‐device2>
 | ||
| 
 | ||
|    where disk-device1 is the replacement disk (for example, sdb) and 
 | ||
|    disk-device2 is the existing healthy disk (for example, sda).
 | ||
| 
 | ||
| 5-Add the replacement disk to the RAID 1 set by issuing the following command:
 | ||
| 
 | ||
| .. opcmd:: add raid <RAID‐1‐device> member <disk‐partition>
 | ||
| 
 | ||
|    where RAID-1-device is the name of the RAID 1 device (for example, md0) and 
 | ||
|    disk-partition is the name of the replacement disk partition 
 | ||
|    (for example, sdb2).
 | ||
| 
 | ||
| Operation
 | ||
| =========
 | ||
| 
 | ||
| This part introduces how to add a disk partition to a RAID-1 set initiates
 | ||
| mirror synchronization, check and display information.
 | ||
| 
 | ||
| .. opcmd:: add raid <RAID‐1‐device> member <disk‐partition>
 | ||
|  
 | ||
|    Use this command to add a member disk partition to the RAID 1 set. Adding a 
 | ||
|    disk partition to a RAID 1 set initiates mirror synchronization, where all 
 | ||
|    data on the existing member partition is copied to the new partition.
 | ||
| 
 | ||
| .. opcmd:: format disk <disk‐device1> like <disk‐device2>
 | ||
| 
 | ||
|    This command is typically used to prepare a disk to be added to a preexisting
 | ||
|    RAID 1 set (of which disk-device2 is already a member).
 | ||
| 
 | ||
| .. opcmd:: show raid <RAID‐1‐device>
 | ||
|    
 | ||
|    shows output for show raid md0 as sdb1 is being added to the RAID 1 
 | ||
|    set and is in the process of being resynchronized.
 | ||
| 
 | ||
|    .. code-block:: none
 | ||
| 
 | ||
|       vyos@vyos:~$ show raid md0
 | ||
|       /dev/md0:
 | ||
|             Version : 00.90
 | ||
|       Creation Time : Wed Oct 29 09:19:09 2008
 | ||
|          Raid Level : raid1
 | ||
|          Array Size : 1044800 (1020.48 MiB 1069.88 MB)
 | ||
|       Used Dev Size : 1044800 (1020.48 MiB 1069.88 MB)
 | ||
|        Raid Devices : 2
 | ||
|       Total Devices : 2
 | ||
|       Preferred Minor : 0
 | ||
|         Persistence : Superblock is persistent
 | ||
|         Update Time : Wed Oct 29 19:34:23 2008
 | ||
|               State : active, degraded, recovering
 | ||
|       Active Devices : 1
 | ||
|       Working Devices : 2
 | ||
|       Failed Devices : 0
 | ||
|       Spare Devices : 1
 | ||
|       Rebuild Status : 17% complete
 | ||
|                UUID : 981abd77:9f8c8dd8:fdbf4de4:3436c70f
 | ||
|              Events : 0.103
 | ||
|         Number   Major   Minor   RaidDevice State
 | ||
|            0       8        1        0      active sync   /dev/sda1
 | ||
|            2       8       17        1      spare rebuilding   /dev/sdb1
 | ||
| 
 | ||
| .. opcmd:: show raid <RAID‐1‐device>
 | ||
|    
 | ||
|    Use this command to display the formatting of a hard disk.
 | ||
| 
 | ||
|    .. code-block:: none
 | ||
| 
 | ||
|       vyos@vyos:~$ show disk sda format
 | ||
|       Disk /dev/sda: 1073 MB, 1073741824 bytes
 | ||
|       85 heads, 9 sectors/track, 2741 cylinders
 | ||
|       Units = cylinders of 765 * 512 = 391680 bytes
 | ||
|       Disk identifier: 0x000b7179   
 | ||
|        Device Boot      Start         End      Blocks   Id  System
 | ||
|       /dev/sda1               6        2737     1044922+  fd  Linux raid autodetect
 | ||
| 
 | ||
|       
 | ||
| 
 |