mirror of
https://github.com/vyos/vyos-documentation.git
synced 2025-10-26 08:41:46 +01:00
Merge pull request #681 from fett0/raid-add-documentation
Raid-1 add documentation (cherry picked from commit 8aedccf83c6c051f8d31b681081a9f6bac97ebbe)
This commit is contained in:
parent
caa20e1167
commit
32a0700cc9
@ -7,4 +7,5 @@ Operation Mode
|
||||
:includehidden:
|
||||
|
||||
information
|
||||
boot-options
|
||||
boot-options
|
||||
raid
|
||||
245
docs/operation/raid.rst
Normal file
245
docs/operation/raid.rst
Normal file
@ -0,0 +1,245 @@
|
||||
.. _raid:
|
||||
|
||||
######
|
||||
RAID-1
|
||||
######
|
||||
|
||||
A Redundant Array of Independent Disks (RAID) uses two or more hard disk drives
|
||||
to improve disk speed, store more data, and/or provide fault tolerance.
|
||||
There are several storage schemes possible in a RAID array, each offering a
|
||||
different combination of storage, reliability, and/or performance.
|
||||
The VyOS system supports a “RAID 1” deployment. RAID 1 allows two or more
|
||||
disks to mirror one another to provide system fault tolerance. In a RAID 1
|
||||
solution, every sector of one disk is duplicated onto every sector of all
|
||||
disks in the array. Provided even one disk in the RAID 1 set is operational,
|
||||
the system continues to run, even through disk replacement (provided that the
|
||||
hardware supports in-service replacement of drives).
|
||||
RAID 1 can be implemented using special hardware or it can be implemented in
|
||||
software. The VyOS system supports software RAID 1 on two disks.
|
||||
The VyOS implementation of RAID 1 allows the following:
|
||||
|
||||
* Detection and reporting of disk failure
|
||||
* The ability to maintain system operation with one failed disk
|
||||
* The ability to boot the system with one failed disk
|
||||
* The ability to replace a failed disk and initiate re-mirroring
|
||||
* The ability to monitor the status of remirroring
|
||||
|
||||
.. _raid_instalation:
|
||||
|
||||
Installation Implications
|
||||
=========================
|
||||
|
||||
The VyOS systems installation utility provides several options for installing
|
||||
to a RAID 1 set. You can:
|
||||
|
||||
* Use the install system to create the RAID 1 set
|
||||
* Use the underlying Linux commands to create a RAID 1 set before running the
|
||||
install system command.
|
||||
* Use a previously-created RAID 1 set.
|
||||
|
||||
.. note:: Before a permanent installation, VyOS runs a live installation
|
||||
|
||||
Configuration
|
||||
=============
|
||||
|
||||
Single disk, install as normal
|
||||
------------------------------
|
||||
|
||||
When the VyOS system is installed, it automatically detects the presence of two
|
||||
disks not currently part of a RAID array. In these cases, the VyOS
|
||||
installation utility automatically offers you the option of configuring RAID 1
|
||||
mirroring for the drives, with the following prompt.
|
||||
|
||||
.. code-block:: none
|
||||
|
||||
Would you like to configure RAID 1 mirroring on them?
|
||||
|
||||
* If you do not want to configure RAID 1 mirroring, enter “No” at the prompt
|
||||
and continue with installation in the normal way.
|
||||
|
||||
Empty 2+ Disk
|
||||
-------------
|
||||
|
||||
If VyOS system detect two identical disks that are not currently part of a
|
||||
RAID-1 set, the VyOS installation utility automatically offers you the option
|
||||
of configuring RAID 1 mirroring for the drives, with the following prompt.
|
||||
|
||||
.. code-block:: none
|
||||
|
||||
Would you like to configure RAID 1 mirroring on them?
|
||||
|
||||
1 - To create a new RAID 1 array, enter “Yes” at the prompt. If the system
|
||||
detects a filesystem on the partitions being used for RAID 1 it will prompt you
|
||||
to indicate whether you want to continue creating the RAID 1 array.
|
||||
|
||||
.. code-block:: none
|
||||
|
||||
Continue creating array?
|
||||
|
||||
2 - To overwrite the old filesystem, enter “Yes”.
|
||||
|
||||
3 - The system informs you that all data on both drives will be erased. You are
|
||||
prompted to confirm that you want to continue
|
||||
|
||||
.. code-block:: none
|
||||
|
||||
Are you sure you want to do this?
|
||||
|
||||
4 - Enter “Yes” at the prompt to retain the current VyOS configuration once
|
||||
installation is complete. Enter “No” to delete the current VyOS
|
||||
configuration.
|
||||
|
||||
.. code-block:: none
|
||||
|
||||
Would you like me to save the data on it before I delete it?
|
||||
|
||||
5 - Enter “Yes” at the prompt to retain the current VyOS configuration once
|
||||
installation is complete. Enter “No” to delete the current VyOS configuration.
|
||||
|
||||
6 - Continue with installation in the normal way.
|
||||
|
||||
|
||||
Present RAID-1
|
||||
--------------
|
||||
|
||||
When the VyOS software on a system with a RAID 1 set already configured,
|
||||
the installation utility will detect the array and will display the following
|
||||
prompt:
|
||||
|
||||
.. code-block:: none
|
||||
|
||||
Would you like to use this one?
|
||||
|
||||
1 - To break apart the current RAID 1 set, enter “No” at the prompt. The
|
||||
|
||||
installation utility detects that there are two identical disks and offers you
|
||||
the option of configuring RAID 1 mirroring on them, displaying the following
|
||||
prompt:
|
||||
|
||||
.. code-block:: none
|
||||
|
||||
Would you like to configure RAID 1 mirroring on them?
|
||||
|
||||
2 - To decline to set up a new RAID 1 configuration on the disks, enter “No”
|
||||
at the prompt. The system prompts you to indicate which partition you would
|
||||
like the system installed on.
|
||||
|
||||
.. code-block:: none
|
||||
|
||||
Which partition should I install the root on? [sda1]:
|
||||
|
||||
3 - Enter the partition where you would like the system installed. The system
|
||||
then prompts you to indicate whether you want to save the old configuration
|
||||
data. This represents the current VyOS configuration.
|
||||
|
||||
.. code-block:: none
|
||||
|
||||
Would you like me to save the data on it before I delete it?
|
||||
|
||||
4 - Enter “Yes” at the prompt to retain the current VyOS configuration once
|
||||
installation is complete. Enter “No” to delete the current VyOS configuration.
|
||||
|
||||
5 - Continue with installation in the normal way.
|
||||
|
||||
|
||||
Detecting and Replacing a Failed RAID 1 Disk
|
||||
--------------------------------------------
|
||||
|
||||
The VyOS system automatically detects a disk failure within a RAID 1 set and
|
||||
reports it to the system console. You can verify the failure by issuing the
|
||||
show raid command.
|
||||
|
||||
To replace a bad disk within a RAID 1 set, perform the following steps:
|
||||
|
||||
1 - Remove the failed disk from the RAID 1 set by issuing the following
|
||||
command:
|
||||
|
||||
.. opcmd:: delete raid RAID‐1‐device member disk‐partition
|
||||
|
||||
where RAID-1-device is the name of the RAID 1 device (for example, md0) and
|
||||
disk-partition is the name of the failed disk partition (for example, sdb2).
|
||||
|
||||
2- Physically remove the failed disk from the system. If the drives are not
|
||||
hot-swappable, then you must shut down the system before removing the disk.
|
||||
|
||||
3 - Replace the failed drive with a drive of the same size or larger.
|
||||
|
||||
4 - Format the new disk for RAID 1 by issuing the following command:
|
||||
|
||||
.. opcmd:: format <disk‐device1> like <disk‐device2>
|
||||
|
||||
where disk-device1 is the replacement disk (for example, sdb) and
|
||||
disk-device2 is the existing healthy disk (for example, sda).
|
||||
|
||||
5-Add the replacement disk to the RAID 1 set by issuing the following command:
|
||||
|
||||
.. opcmd:: add raid <RAID‐1‐device> member <disk‐partition>
|
||||
|
||||
where RAID-1-device is the name of the RAID 1 device (for example, md0) and
|
||||
disk-partition is the name of the replacement disk partition
|
||||
(for example, sdb2).
|
||||
|
||||
Operation
|
||||
=========
|
||||
|
||||
This part introduces how to add a disk partition to a RAID-1 set initiates
|
||||
mirror synchronization, check and display information.
|
||||
|
||||
.. opcmd:: add raid <RAID‐1‐device> member <disk‐partition>
|
||||
|
||||
Use this command to add a member disk partition to the RAID 1 set. Adding a
|
||||
disk partition to a RAID 1 set initiates mirror synchronization, where all
|
||||
data on the existing member partition is copied to the new partition.
|
||||
|
||||
.. opcmd:: format <disk‐device1> like <disk‐device2>
|
||||
|
||||
This command is typically used to prepare a disk to be added to a preexisting
|
||||
RAID 1 set (of which disk-device2 is already a member).
|
||||
|
||||
.. opcmd:: show raid <RAID‐1‐device>
|
||||
|
||||
shows output for show raid md0 as sdb1 is being added to the RAID 1
|
||||
set and is in the process of being resynchronized.
|
||||
|
||||
.. code-block:: none
|
||||
|
||||
vyos@vyos:~$ show raid md0
|
||||
/dev/md0:
|
||||
Version : 00.90
|
||||
Creation Time : Wed Oct 29 09:19:09 2008
|
||||
Raid Level : raid1
|
||||
Array Size : 1044800 (1020.48 MiB 1069.88 MB)
|
||||
Used Dev Size : 1044800 (1020.48 MiB 1069.88 MB)
|
||||
Raid Devices : 2
|
||||
Total Devices : 2
|
||||
Preferred Minor : 0
|
||||
Persistence : Superblock is persistent
|
||||
Update Time : Wed Oct 29 19:34:23 2008
|
||||
State : active, degraded, recovering
|
||||
Active Devices : 1
|
||||
Working Devices : 2
|
||||
Failed Devices : 0
|
||||
Spare Devices : 1
|
||||
Rebuild Status : 17% complete
|
||||
UUID : 981abd77:9f8c8dd8:fdbf4de4:3436c70f
|
||||
Events : 0.103
|
||||
Number Major Minor RaidDevice State
|
||||
0 8 1 0 active sync /dev/sda1
|
||||
2 8 17 1 spare rebuilding /dev/sdb1
|
||||
|
||||
.. opcmd:: show raid <RAID‐1‐device>
|
||||
|
||||
Use this command to display the formatting of a hard disk.
|
||||
|
||||
.. code-block:: none
|
||||
|
||||
vyos@vyos:~$ show disk sda format
|
||||
Disk /dev/sda: 1073 MB, 1073741824 bytes
|
||||
85 heads, 9 sectors/track, 2741 cylinders
|
||||
Units = cylinders of 765 * 512 = 391680 bytes
|
||||
Disk identifier: 0x000b7179
|
||||
Device Boot Start End Blocks Id System
|
||||
/dev/sda1 6 2737 1044922+ fd Linux raid autodetect
|
||||
|
||||
|
||||
|
||||
Loading…
x
Reference in New Issue
Block a user