Currently ACS waits for 15 seconds (hard coded) for hot-plugged NIC in VR to get detected by guest OS.
The time taken to detect hot plugged NIC in guest OS depends on type of NIC adapter like (E1000, VMXNET3, E1000e etc.)
and guest OS itself. In uncommon scenarios the NIC detection may take longer time than 15 seconds,
in such cases NIC hotplug would be treated as failure which results in VPC tier configuration failure.
Alternatively making the wait timeout for NIC adapter hotplug as configurable will be helpful for admins in such scenarios.
Also in future if VMware introduces new NIC adapter types which may take time to get detected by guest OS, it is good to have flexibility of
configuring the wait timeout as fallback mechanism in such scenarios.
Signed-off-by: Sateesh Chodapuneedi <sateesh.chodapuneedi@accelerite.com>
CLOUDSTACK-9456: Migrate master to Spring 4.xThis changes makes CloudStack use spring 4:
```
- Bump spring-framework version to 4.x and Jetty to version that runs with JDK7
- Bump servet dependency version
- Migrates various xmls to use version independent schema uris
```
Outstanding issue:
- Testing of various non-standard plugins such as network and storage plugins etc.
Since, this is a big change pinging for review -- @jburwell @karuturi @wido @murali-reddy @abhinandanprateek @DaanHoogland @GaborApatiNagy @JayapalUradi @kishankavala @K0zka @nvazquez @rafaelweingartner @pyr and others
@blueorangutan package
* pr/1638:
CLOUDSTACK-9456: Update Spring version in maven poms
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
Issue
====
Exception occured while creating the CPVM in the VmWare Setup using standard vswitches.
StartCommand failed due to Exception: com.vmware.vim25.AlreadyExists
message: [] com.vmware.vim25.AlreadyExistsFaultMsg: The specified key, name, or identifier already exists
Fix
===
Ensure synchronization while attempting to create port group such that simultaneous attempts are not made with same port group name on same ESXi host.
Signed-off-by: Sateesh Chodapuneedi <sateesh.chodapuneedi@accelerite.com>
- Bump spring-framework version to 4.x and Jetty to version that runs with JDK8
- Bump servet dependency version
- Migrate spring xmls to version 4, fixes schema locations that are 3.0
dependent in various xmls.
- Fix failing tests due to spring upgrade
(Thanks @marcaurele Marc-Aurèle Brothier for fixing them)
* Fix test DeploymentPlanningManagerImplTest
* Fix GloboDNS test
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
CLOUDSTACK-9564: Fix memory leaks in VmwareContextPoolIn a recent management server crash, it was found that the largest contributor
to memory leak was in VmwareContextPool where a registry is held (arraylist)
that grows indefinitely. The list itself is not used anywhere or consumed. There
exists a hashmap (pool) that returns a list of contexts for existing poolkey
(address/username) that is used instead.
This fixes the issue by removing the arraylist registry, and limiting the
length of the context list for a given poolkey.
@blueorangutan package
* pr/1729:
CLOUDSTACK-9564: Fix memory leaks in VmwareContextPool
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
In a recent management server crash, it was found that the largest contributor
to memory leak was in VmwareContextPool where a registry is held (arraylist)
that grows indefinitely. The list itself is not used anywhere or consumed. There
exists a hashmap (pool) that returns a list of contexts for existing poolkey
(address/username) that is used instead.
This fixes the issue by removing the arraylist registry, and limiting the
length of the context list for a given poolkey.
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
CLOUDSTACK-9379: Support nested virtualization at VM level on VMware Hypervisor## Introduction
[JIRA TICKET](https://issues.apache.org/jira/browse/CLOUDSTACK-9379)
It is desired to support nested virtualization at VM level for VMware hypervisor. Current behaviour supports enabling/desabling global nested virtualization by modifying global config `'vmware.nested.virtualization'`. It is wished to improve this feature, having control at VM level instead of a global control only.
A new global configuration is added, to enable/disable VM nested virtualization control: `'vmware.nested.virtualization.perVM'`. Default value=false
After a vm deployment or start command, vm params include `'nestedVirtualizationFlag'` key and its value is:
- true -> nested virtualization enabled
- false -> nested virtualization disabled
**We will determinate nested virtualization enabled/disabled by examining this 3 values:**
- **(1)** global configuration `'vmware.nested.virtualization'` value
- **(2)** global configuration `'vmware.nested.virtualization.perVM'` value
- **(3)** `'nestedVirtualizationFlag'` value in `user_vm_details` if present, `null` if not.
Using this 3 values, there are different use cases:
- **(1)** = TRUE, **(2)** = TRUE, **(3)** is null -> _ENABLED_
- **(1)** = TRUE, **(2)** = TRUE, **(3)** = TRUE -> _ENABLED_
- **(1)** = TRUE, **(2)** = TRUE, **(3)** = FALSE -> _DISABLED_
- **(1)** = TRUE, **(2)** = FALSE, **(3)** indifferent -> _ENABLED_
- **(1)** = FALSE, **(2)** = TRUE, **(3)** is null -> _DISABLED_
- **(1)** = FALSE, **(2)** = TRUE, **(3)** = TRUE -> _ENABLED_
- **(1)** = FALSE, **(2)** = TRUE, **(3)** = FALSE -> _DISABLED_
- **(1)** = FALSE, **(2)** = FALSE, **(3)** indifferent -> _DISABLED_
* pr/1542:
CLOUDSTACK-9379: Support nested virtualization at VM level on VMware Hypervisor
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
CLOUDSTACK-9491: incorrect parsing of device list to find ethernet index of plugged NICIn VmwareResource, findRouterEthDeviceIndex() method find ethernet interface index given
the mac address. This method is used, once a nic is plugged to determine ethernet interface.
"/proc/sys/net/ipv4/conf" from the VR and looped through the devices to find the right
ethernet interface. Howver current logic read it once, and loops through the device list.
Its observerd device may not show up '/proc/sys/net/ipv4/conf' immediatly once NIC is plugged
in the VM from vCenter.
Fix ensured, while waiting for 15 sec in the loop, read the latest content from /proc/sys/net/ipv4/conf
, so that right device list is processed.
Manual tested VPC scenarios of adding new tiers which uses findRouterEthDeviceIndex, to find the guest/public network ethernet index.
* pr/1681:
CLOUDSTACK-9491: incorrect parsing of device list to find ethernet index of plugged NIC
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
CLOUDSTACK-9503: Increased the VR script timeout. Most of the changes are about converting int/long time values to joda Duration.
* pr/1745:
CLOUDSTACK-9503: Increased the VR script timeout. Most of the changes are about converting int/long time values to joda Duration.
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
CLOUDSTACK-9502: DS template copies dont get deleted in VMware ESXi with multiple clusters and zone wide storage (include CLOUDSTACK-9386 into 4.9 release branch)Include #1560 into 4.9 release branch
* pr/1676:
CLOUDSTACK-9502: DS template copies don’t get deleted in VMware ESXi with multiple clusters and zone wide storage
Signed-off-by: John Burwell <meaux@cockamamy.net>
* 4.9:
CLOUDSTACK-8830: Fix for vm snapshots in Vmware, could not create vm snapshot until 12 minutes after vm creation due to vCenter sent null name on snpashot recent task
In VmwareResource, findRouterEthDeviceIndex() method find ethernet interface index given
the mac address. This method is used, once a nic is plugged to determine ethernet interface.
"/proc/sys/net/ipv4/conf" from the VR and looped through the devices to find the right
ethernet interface. However current logic read it once, and loops through the device list.
Its observerd device may not show up '/proc/sys/net/ipv4/conf' immediatly once NIC is plugged
in the VM from vCenter.Fix ensured, while waiting for 15 sec in the loop, read the latest
content from /proc/sys/net/ipv4/conf, so that right device list is processed.
CLOUDSTACK-9428: Fix for CLOUDSTACK-9211 - Improve performance of 3D GPU support in cloud-plugin-hypervisor-vmwareJIRA TICKET: https://issues.apache.org/jira/browse/CLOUDSTACK-9428
### Introduction
On #1310 passing vRAM size to support 3D GPU problem was addressed on VMware. It was found out that it could be improved to increase performance by reducing extra API calls, as we'll describe later
### Improvement
On WMware, `VmwareResource` manages execution of `StartCommand.` Before sending power on command to ESXi hypervisor, vm is configured by calling `reconfigVMTask` web method on vSphere's client `VimPortType` web service.
It was found out that we were using this method 2 times when passing vRAM size, as it implied creating a new vm config spec only editing video card specs and making an extra call to `reconfigVMTask.`
We propose reducing the extra web service call by adjusting vm's config spec. This way video card gets properly configured (when passing vRAM size) in the same configure call, increasing performance.
### Use case (passing vRAM size)
* Deploy a new VM, let its id be X
* Stop VM
* Execute SQL, where X is vm's id and Z is vRAM size (in kB):
````
INSERT INTO cloud.user_vm_details (vm_id, name, value) VALUES (X, 'mks.enable3d', 'true');
INSERT INTO cloud.user_vm_details (vm_id, name, value) VALUES (X, 'mks.use3dRenderer', 'automatic');
INSERT INTO cloud.user_vm_details (vm_id, name, value) VALUES (X, 'svga.autodetect', 'false');
INSERT INTO cloud.user_vm_details (vm_id, name, value) VALUES (X, 'svga.vramSize', Z);
````
* Start VM
* pr/1605:
CLOUDSTACK-9428: Add marvin test
CLOUDSTACK-9428: Fix for CLOUDSTACK-9211 - Improve performance
Signed-off-by: Rafael Weingärtner <rafael@apache.org>
Often, patch and security releases do not require schema migrations or
data migrations. However, if an empty upgrade class and associated
scripts are not defined, the upgrade process will break. With this
change, if a release does not have an upgrade, a noop DbUpgrade is added
to the upgrade path. This approach allows the upgrade to proceed and
for the database to properly reflect the installed version. This change
should make the release process simpler as RMs no longer need to
rememeber to create this boilerplate code when starting a new release.
Beginning with the 4.8.2.0 and 4.9.1.0 releases, the project will
formally adopt a four (4) position release number to properly accomodate
rekeases that contain only CVE fixes. The DatabaseUpgradeChecker and
Version classes made assumptions that they would always parse and
compare three (3) position version numbers. This change adds the
CloudStackVersion value object that supports both three (3) and four (4)
version numbers. It encapsulates version comparsion logic, as well as,
the rules to allow three (3) and four (4) to interoperate.
* Modifies DatabaseUpgradeChecker to handle derive an upgrade path for
a version that was not explicitly specified. It determines the
releases the first release before it with database migrations and uses
that list as the basis for the list for version being calculated. A
noop upgrade is then added to the list which causes no schema changes
or data migrations, but will update the database to the version.
* Adds unit tests for the upgrade path calculation logic in
DatabaseUpgradeChecker
* Removes dummy upgrade logic for the 4.8.2.0 introduced in previous
versions of this patch
* Introduces the CloudStackVersion value object which parses and
compares three (3) and four (4) position version numbers. This class
is intended to replace com.cloud.maint.Version.
* Adds the junit-dataprovider dependency -- allowing test data to be
concisely generated separately from the execution of a test case.
Used extensively in the CloudStackVersionTest.
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
CLOUDSTACK-8800 : Improved the listVirtualMachines API call to include memory utilization information for a VMThis PR introduces the changes proposed in PR #780 with some work to make the code null safe.
During this PR, I have also removed some unused code.
* pr/1444:
Removed unnecessary check when creating the “userVmResponse” object.
Fixed issues from CLOUDSTACK-8800 that were introduced in PR 780
CLOUDSTACK-8800 : Improved the listVirtualMachines API call to include memory utilization information for a VM for xenserver,kvm and for vmware.
Signed-off-by: Will Stevens <williamstevens@gmail.com>
- Improve disk chain usage while attaching, migrating disks
- Gets root disk controller based diskDeviceBusName from volume's chain info
- Refactor and move VirtualMachineDiskInfo to cloud-utils
- Allows mixing of scsi controller types
- Fixes a NPE case with map passed as null, for example in case of detach volume
command
- Use a osdefault translator that allow use of recent os types added (enums of
which) are not available in the sdk
Signed-off-by: Rohit Yadav <rohit.yadav@shapeblue.com>
CLOUDSTACK-8800 : Improved the listVirtualMachines API call to include memory utilization information for a VMfor xenserver,kvm and for vmware.
* pr/780:
CLOUDSTACK-8800 : Improved the listVirtualMachines API call to include memory utilization information for a VM for xenserver,kvm and for vmware.
Signed-off-by: Kishan Kavala <kishan@apache.org>