when secondary storage is mounted as read-only, changing permission of files on it will fail. But we should still stick to current mount point instread of
returning a wrong mount point /mnt/sec
Initial patch for VXLAN support.
Fully functional, hopefully, for GuestNetwork - AdvancedZone.
Patch Note:
in cloudstack-server
- Add isolation method VXLAN
- Add VxlanGuestNetworkGuru as plugin for VXLAN isolation
- Modify NetworkServiceImpl to handle extended vNet range for VXLAN isolation
- Add VXLAN isolation option in zoneWizard UI
in cloudstack-agent (kvm)
- Add modifyvxlan.sh script that handle bridge/vxlan interface manipulation script
-- Usage is exactly same to modifyvlan.sh
- BridgeVifDriver will call modifyvxlan.sh instead of modifyvlan.sh when VXLAN is used for isolation
Database changes:
- No change in database structure.
- VXLAN isolation uses same tables that VLAN uses to store vNet allocation status.
Known Issue:
- Some resource still says 'VLAN' in log even if VXLAN is used
- in UI, "Network - GuestNetworks" dosen't display VNI
-- VLAN ID field displays "N/A"
This failed due to a RAW -> QCOW2 conversion (again).
The current code still makes to much assumptions about everything always
being QCOW2 while that is not always true.
UI support for baremetal PXE server
CloudStack CLOUDSTACK-1364
UI support for baremetal DHCP server
Conflicts:
plugins/hypervisors/baremetal/src/com/cloud/baremetal/networkservice/BareMetalPingServiceImpl.java
plugins/hypervisors/baremetal/src/com/cloud/baremetal/networkservice/BaremetalKickStartServiceImpl.java
plugins/hypervisors/baremetal/src/com/cloud/baremetal/networkservice/BaremetalPxeManagerImpl.java
KVM - Create template from volume
Vmware - Create template from volume / Create template from snapshot
send the physical size in the copycommand which accordingly will populate template store ref and the usage_event tables with the right physical size
Signed off by : nitin mehta<nitin.mehta@citrix.com>
XS Creating templates from volume - send the physical size in the copycommand which accordingly will populate template store ref and the usage_event tables with the right physical size
Signed off by : nitin mehta<nitin.mehta@citrix.com>
If all the VM's volumes are on zone wide primary storage pool then live migration of the VM would not involve storage migration. Hence MigrateVM API would be called against MigrateVMWithVolume. So far PrepareForMigrationCommand handled scenarios of VM moving across hosts within a cluster, but with zone wide primary storage in picture this command need to handle scenarios of VM moving across clusters. Try to find the VM in datacenter if not found within cluster.
Signed-off-by: Sateesh Chodapuneedi <sateesh@apache.org>