details has information on cores per socket, create an instance accordingly. The vm record
is populated with information on how many cores should be allowed in a socket.
a host to the pool it may take a little longer to join the pool. Increased the time the
resource waits and checks to make sure the host has joined as slave to the pool.
Include the createTemplateFromSnapshot in the storageprocessor.
Signed-off-by: Prasanna Santhanam <tsp@apache.org>
(cherry picked from commit e8383121c60e7c815ba1990df1e8a440f7d87188)
Send success answer of type CopyCmdAnswer with full snapshot backup path in secondary store (image store role)
Signed-off-by: Sateesh Chodapuneedi <sateesh@apache.org>
- Move vnetBridge clean up function from LibvirtComputingResource to BridgeVifDriver
-- since only BridgeVifDriver have to handle this event
- LibvirtComputingResource now properly call VifDriver.unplug() when it receives UnPlugCommand
- Remove not working and no longer used method getVnet(String) from VirtualMachineName
- Remove not working and no longer used method getVnet() from StopCommand
- Remove unused constructer StopCommand(VirtualMachine, String, boolean) from StopCommand
- Remove unused member vnet from StopCommand
- Remove unused member _modifyVlanPath from OvsVifDriver
Tested with 2 KVM hosts and confirmed it correctly manipulate vnetBridge with start, stop, migrate, plug, and unplug event
Signed-off-by: Hugo Trippaers <htrippaers@schubergphilis.com>
Fix the name of the interface id in extra config, so the nic is found up using the nic uuid instead of the vm id.
getVlanInfo should return null when the nic is plugged on a Lswitch network.
On a distributed portgroup all vms should be connected to a single
portgroup and set a specific vlan on the port. On a standard switch each nic should have its own portgroup with a dedicated vlan (not related to CS vlans)
For legacy zones insist on the old model of asking for credentials for each cluster being added.
For non-legacy zones check if username & password are provided. If either or both not provided, try to retrieve & use the credentials from database, which are provided earlier while adding VMware DC to zone.
This lets user to not specify credentials while adding VMware cluster to zone, if the credentials are same as that of provided while adding VMware DC to zone.
Signed-off-by: Sateesh Chodapuneedi <sateesh@apache.org>
Description:
a) Fixing NPE when wrong path is provided for primary datastore.
b) No error dialog shows up in GUI when wrong path is provided,
after NPE fix - propagating exception upward.
c) If the KVM agent is down, an invalid datastore gets logged in
storage_pool table and doesn't get removed, so it shows up
in the GUI in the list of datastores - fixing this as well.